Operator's Manual

5.Installthecoverorientingtherubberoutletvalvein
adownwardposition—betweenapproximately5:00
to7:00whenviewedfromtheend.
6.Resettheindicator(Figure52)ifitshowsred.
ServicingtheEngineOiland
Filter
ServiceInterval:Aftertherst50hours
Every150hours
Changeoilandlterinitiallyaftertherst50hoursof
operation,thereafterchangeoilandlterevery150
hours.
1.Removedrainplug(Figure56)andletoilowinto
drainpan.Whenoilstops,installdrainplug.
Figure56
1.Drainplugs
2.Removeoillter(Figure57).Applyalightcoatof
cleanoiltothenewltersealbeforescrewingiton.
Donotover-tighten.
Figure57
1.Oillter
3.Addoiltothecrankcase.Capacityis7.5qt.(7L)
withlter.
AdjustingThrottle
1.Positionthrottleleverforwardsoitstopsagainst
seatbaseslot.
2.Loosenthethrottlecableconnectorontheleverarm
attheinjectionpump(Figure58).
Figure58
1.Injectionpumpleverarm
2.Connector
3.Holdtheinjectionpumpleverarmagainstthehigh
idlestopandtightenthecableconnector.
Note:Whentightened,thecableconnectormustbe
freetoswivel.
4.Torquethelocknut,usedtosetthefrictiondeviceon
thethrottlelever,to40-55in-lb.Themaximumforce
requiredtooperatethethrottlelevershouldbe20lb.
41