Operator's Manual

g008891
Figure39
1.Fuel-injectionpumpbleedscrew
4.Turnthekeyintheignitionswitchtothe
ONposition.Theelectricfuelpumpbegins
operation,therebyforcingairoutaroundthe
air-bleedscrew.
Note:LeavethekeyintheONpositionuntila
solidstreamoffuelowsoutaroundthescrew.
5.TightenthescrewandturnthekeytotheOFF
position.
Note:Normallytheengineshouldstartafterthe
abovebleedingproceduresarefollowed.However,if
theenginedoesnotstart,airmaybetrappedbetween
theinjectionpumpandinjectors;refertoBleedingAir
fromtheInjectors(page42).
Understandingthe
DiagnosticLight
Themachineisequippedwithadiagnosticlight
thatindicatesiftheelectroniccontrollersensesan
electronicmalfunction.Thediagnosticlightislocated
onthecontrolpanel(Figure40).Whentheelectronic
controllerisfunctioningcorrectlyandyoumovethe
keyswitchtotheONposition,thecontrollerdiagnostic
lightturnsonfor3secondsandturnofftoindicate
thatthelightisworkingproperly.Iftheengineshuts
off,thenthelightturnsonsteadyuntiltheyouchange
keyposition.Thelightblinksifthecontrollerdetectsa
malfunctionintheelectricalsystem.Thelightstops
blinkingandautomaticallyresetswhenyouturnthe
keyswitchtotheOFFpositiononcethefaulthasbeen
resolved.
g020251
Figure40
1.Diagnosticlight
Whenthecontrollerdiagnosticlightblinks,1of
thefollowingproblemshasbeendetectedbythe
controller:
Anoutputhasbeenshorted.
Anoutputisopencircuited.
Usingthediagnosticdisplay,determinewhichoutput
ismalfunctioning;refertoCheckingtheInterlock
Switches(page31).
Ifthediagnosticlightisnotilluminatedwhenthekey
switchisintheONposition,thisindicatesthatthe
electroniccontrollerisnotoperating.Possiblecauses
areasfollows:
Theloop-backisnotconnected.
Thelightisburnedout.
Fusesareblown.
Itisnotfunctioningcorrectly.
Checktheelectricalconnections,inputfuses,and
diagnosticlightbulbtodeterminethemalfunction.
Ensurethattheloop-backconnectorissecuredto
thewireharnessconnector.
30