Tostartandstoptheengine:
Openfuelshut-offvalve.
Verifythatthetractionandreeldrivecontrol
leversonhandleareinNeutralposition.
Movetheon/offswitch,locatedonthecontrol
panel,toONposition,setchoketofullchoke
position(coldstart)andthrottletohalfthrottle.
Pullstartercordtostartengine.
MovethrottletoSlowandon/offswitchtoOff
positiontostopengine.
Totransportmowerfromoneareatoanother:
Installtransportwheels.
Disengagereeldrive.
Startengine.
Pressdownonhandletoraisefrontofmower
andengagetractiondrive.
Beforebeginningmowingoperation:
Disengagetractiondrive.
Stopengine.
Removetransportwheels.
Startengine
Engagereeldrive.
Usingthemachinedemandsattention.Toprevent
lossofcontrol:
Donotdriveclosetosandtraps,ditches,creeks,
orotherhazards.
Reducespeedwhenmakingsharpturns.Avoid
suddenstopsandstarts.
Whennearorcrossingroads,alwaysyieldthe
right-of-way.
Thegrassbasketmustbeinplace,duringthe
mowingoperation,formaximumsafety.Shutthe
engineoffbeforeemptyingthebasket.
Donottouchtheengine,mufer,orexhaustpipe
whiletheengineisrunningorsoonafterithas
stoppedbecausetheseareascouldbehotenough
tocauseburns.
Whenapersonorpetappearsunexpectedlyin
ornearthemowingarea,stopmowing.Careless
operation,combinedwithterrainangles,ricochets,
orimproperlypositionedguardscanleadtothrown
objectinjuries.Donotresumemowinguntilthe
areaiscleared.
MaintenanceandStorage
Checkallfuellinesfortightnessandwearona
regularbasis.Tightenorrepairthemasneeded.
Iftheenginemustberunningtoperforma
maintenanceadjustment,keephands,feet,clothing,
andanypartsofthebodyawayfromthecuttingunit,
attachmentsandanymovingparts.Keepeveryone
away.
Toensuresafetyandaccuracy,haveanAuthorized
ToroDistributorcheckthemaximumenginespeed
withatachometer.Maximumgovernedenginespeed
shouldbe3600RPM.
Ifmajorrepairsareeverneededorifassistanceis
desired,contactanAuthorizedToroDistributor.
UseonlyToro-approvedattachmentsand
replacementparts.Thewarrantymaybevoidedif
usedwithunapprovedattachments.
SoundPowerLevel-Flex18
Thisunithasaguaranteedsoundpowerlevelof96dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinEN11094.
SoundPressureLevel-Flex18
Thisunithasasoundpressurelevelattheoperator’s
earof84dBA,whichincludesanUncertaintyValue(K)
of1dBA.
Soundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
VibrationLevel-Flex18
Hand-Arm
Measuredvibrationlevelforrighthand=2.36m/s
2
Measuredvibrationlevelforlefthand=2.47m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtothe
proceduresoutlinedinEN836.
SoundPowerLevel-Flex21
Thisunithasaguaranteedsoundpowerlevelof97dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinEN11094.