Service Manual
Rev. H
Greensmaster 3250−D
Page 5 − 19
Electrical System (Rev. C)
Lower Reels Time Delay
This is a solid state timer. Upon the application of power,
the load is energized and the time delay is started. After
6 seconds the load is de−energized.
1. Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After 6 seconds, there should
be no voltage across the load.
2. Disconnect timer from 12VDC source and test load.
Figure 23
TIME
DELAY
Figure 24
32 1
45
LOAD
INPUT VOLTAGE
TIMING
+
−
RESISTOR
Electrical
System