Service Manual

Rev. J
Greensmaster 3250--D
Hydraulic System (Rev. I)
Page 4 -- 48
Reel Motor Case Drain Flow Test (Using Tester with Flowmeter and Pressure Gauge)
MEASURING
M1
M2
M3
CONTAINER
FROM MANIFOLD
PORT MA
TO MANIFOLD
PORT MB
TO HYDRAULIC
RESERVOIR
RIGHT MOTOR
RETURN
LEFT MOTOR
RETURN
LEFT MOTOR
CASE DRAIN
RIGHT MOTOR
CASE DRAIN
REAR MOTOR
CASE DRAIN
REAR MOTOR
RETURN
RIGHT
MOTOR
REAR
LEFT
MOTOR
MOTOR
High Pressure
Low Pressure
Return or Suction
Flow