Service Manual

TRIFLEX DIAGNOSTIC FAULT CODE QUICK REFERENCE TABLE Revision B Page 1
GREENSMASTER 3300, 3400, 3320, 3420 TRIFLEX
DIAGNOSTIC FAULT CODE QUICK REFERENCE TABLE
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional Notes
Service Actions
11
Reel Speed
Potentiometer Bad
Master
This fault is reported when the
reel speed potentiometer
reading is out of range,
indicating either an open or
short circuit.
1) Test the circuit wiring
2) Replace the potentiometer
12
Line Contactor is
Open
S/G
This fault is reported when the
line contactor fault indicates a
fault associated with control of
the 48 Vdc contactor. If the 48
Vdc logic and Bus voltage of the
starter/generator have more
than an 8 Vdc difference when
the contactor is engaged, this
fault will be reported.
The main contactor
exists in the 48 Vdc
system to connect the
48 Vdc battery pack
with the
starter/generator and
reel motor controllers.
The starter/generator
controller determines
when the main
contactor is engaged.
1) Check the voltage across the
coil of the contactor. If the coil is
energized by the
starter/generator, the voltage
should be approximately 48 Vdc.
2) Check the voltage across the
contactor. It should be 0 Vdc if
the contactor is closed.
3) Manually test the functionality of
the contactor using the battery
and jumpers.
4) Replace the contactor if tests
fail.
13
High Temperature
Warning - Cutting
Unit 1
Cutting unit
This fault is reported when the
cutting unit controller
temperature exceeds 90 °C
(195 °F). When the 90 °C
threshold is reached, the fault
reports and the current being
sent to the motor is limited on a
linear basis until 100 °C (212 °F)
is reached. If either the motor
controller or the cutting unit
motor reach 100 °C, the cutting
unit is shut down. This fault is
not produced by a bad sensor.
If the fault continues to
occur at relatively low
loads, replace the
cutting unit electric
motor.
1) Let the machine cool.
2) Inspect the cutting unit to ensure
the reel spins freely, without
binding.
3) Reduce the reel speed.
4) Reduce the mowing speed.
5) If the fault is intermittent, check
the 48 Vdc ground to the motor.