Service Manual

TRIFLEX DIAGNOSTIC FAULT CODE QUICK REFERENCE TABLE Revision A Page 20
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional Notes
Service Actions
Internal Regulator
Undervolt CU3
Cutting unit
This fault is reported when
system voltage drops below the
8.5 Vdc minimum. This fault will
disable the motor.
The TEC will disable
the cutting units.
Replace the cutting unit motor.
121
Invalid Hall State
CU1
Cutting unit
This fault is reported when an
invalid hall state is indicated.
This fault does not
report until the cutting
until motor begins to
spin.
Replace the motor on cutting
unit 1.
Invalid Hall State
CU2
Cutting unit
This fault is reported when an
invalid hall state is indicated.
This fault does not
report until the cutting
unit motor begins to
spin.
Replace the motor on cutting
unit 2.
123
Invalid Hall State
CU3
Cutting unit
This fault is reported when an
invalid hall state is indicated.
This fault does not
report until the cutting
unit motor begins to
spin.
Replace the motor on cutting
unit 3.
Invalid Hall State
S/G
Cutting unit
This fault is reported when an
invalid hall state is indicated.
This fault will not
disable the machine’s
functionality.
Replace the Starter/Generator
motor.
125
Short Detected
CU1
Master
This fault is reported when the
CU1 controller circuit board has
an internal short.
The TEC will stop the
engine and open the
contactor.
1) Unplug both of the connectors
from cutting unit 1 to start the
vehicle.
2) Replace the motor on cutting
unit 1.
Short Detected
CU2
Master
This fault is reported when the
CU2 controller circuit board has
an internal short.
The TEC will stop the
engine and open the
contactor.
1) Unplug both of the connectors
from cutting unit 2 to start the
vehicle.
2) Replace the motor on cutting
unit 2.
127
Short Detected
CU3
Master
This fault is reported when the
CU3 controller circuit board has
an internal short.
The TEC will stop the
engine and open the
contactor.
1) Unplug both of the connectors
from cutting unit 3 to start the
vehicle.
2) Replace the motor on cutting
unit 3.
Short Detected
CU Unknown
Master
This fault is reported when an
unidentified circuit board has an
internal short. CAN bus network
communication still exists with
all cutting units.
The TEC will stop the
engine and open the
contactor.
Unplug both of the connectors
from all 3 cutting units to start
the vehicle.