ConnectingtheBatteries
1.Ensurethatthebatteryterminalsarecleanand
freeofoxidation.
2.Connectthemainpositive-batterycable(red)
betweenthebankofbatteriesandthemachine
(Figure38).
3.Connectthemainnegative-batterycable(black)
betweenthebankofbatteriesandthemachine
(Figure38).
4.T orquethenutssecuringallofthebatterycables
untiltheretainersecurelygripsthebattery.
5.CoatthebatteryterminalswithT oro
battery-terminalprotector.
6.Ensurethattherubberbootsoneachbattery
cablearesecurelyseatedoverthebattery
terminals.
7.Insertthekeyintothekeyswitchandrotatethe
switchtotheONposition.
8.Lowerthecargobed,rotatethekeyswitchto
theOFFposition,andremovethekey.
StoringtheBatteries
Chargethebatteriesfullybeforeplacingthemachine
intostorage.Plugthechargerintoawalloutletwhile
themachineandbatteriesareinstorage.Leave
thechargerpluggedintoawalloutletandcharging
receptacleduringstoragetoensurethatthebatteries
staychargedanddonotfreeze;otherwise,chargethe
batteriesatleastonceamonth.
Important:Ifthemachinecannotbeplugged
induringstorage,fullychargethebatteriesat
leastonceamonth.Thebatteriesself-discharge
overlongperiodsoftime,whichmaydamagethe
batteriestothepointofbeingunusable,evenif
thebatteriesarenew.
ReplacingtheFuses
Thereare4fusesintheelectricalsystem;theother
slotsareopenforoptions.Theyarelocatedunderthe
seatassemblybehindabatteryontherightsideof
themachine(Figure39).
Mainpower10A
Electricrelay20A
USBpowerpoint
5A
Headlights10A
Optionalliftkit—open
15A
Horn—optional(standardon
internationalmodelsonly)
30A
g277605
Figure39
1.Fuseblock