Operator's Manual
ElectricalSystem
Maintenance
ServicingtheBattery
ServiceInterval:Every25hours—Checkthe
electrolytelevelandcleanthebattery.
Every25hours—Checkthebattery
cableconnections.
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandleadcompounds,
chemicalsknowntotheStateofCalifornia
tocausecancerandreproductiveharm.
Washhandsafterhandling.
DANGER
Batteryelectrolytecontainssulfuricacidwhichisa
deadlypoisonandcausessevereburns.
•Donotdrinkelectrolyteandavoidcontactwith
skin,eyes,orclothing.Wearsafetyglassesto
shieldyoureyesandrubberglovestoprotect
yourhands.
•Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
Thebatteryelectrolytelevelmustbeproperlymaintained
andthetopofthebatterykeptclean.Ifthemachineis
storedinalocationwheretemperaturesareextremely
high,thebatterywillrundownmorerapidlythanif
themachineisstoredinalocationwheretemperatures
arecool.
Checktheelectrolytelevelevery25operatinghoursor,
ifmachineisinstorage,every30days.
Maintainthecelllevelwithdistilledordemineralized
water.Donotllthecellsabovethebottomofthesplit
ringinsideeachcell.
Keepthetopofthebatterycleanbywashingit
periodicallywithabrushdippedinammoniaor
bicarbonateofsodasolution.Flushthetopsurfacewith
wateraftercleaning.Donotremovethellcapswhile
cleaning.
Thebatterycablesmustbetightontheterminalsto
providegoodelectricalcontact.
WARNING
Incorrectbatterycableroutingcoulddamagethe
machineandcablescausingsparks.Sparkscan
causethebatterygassestoexplode,resultingin
personalinjury.
•Always
disconnect
thenegative(black)battery
cablebeforedisconnectingthepositive(red)
cable.
•Always
connect
thepositive(red)batterycable
beforeconnectingthenegative(black)cable.
Ifcorrosionoccursattheterminals,disconnectthe
cables(negative(–)cablerst)andscrapeclampsand
terminalsseparately.Reconnectthecables(positive(+)
cablerst)andcoattheterminalswithpetroleumjelly.
WARNING
Batteryterminalsormetaltoolscouldshortagainst
metaltractorcomponentscausingsparks.Sparks
cancausethebatterygassestoexplode,resulting
inpersonalinjury.
•Whenremovingorinstallingthebattery,donot
allowthebatteryterminalstotouchanymetal
partsofthemachine.
•Donotallowmetaltoolstoshortbetween
thebatteryterminalsandmetalpartsofthe
machine.
22