FuelSystem
Maintenance
ReplacingtheFuelFilter
ServiceInterval:Every600hours/Yearly(whichever
comesrst)
Important:Donotinstalladirtylterafterithas
beenremovedfromthefuelline.
1.RefertoPreparingtheMachineforMaintenance
(page17).
2.Allowthemachinetocooldown.
3.Placeacleancontainerunderthefuellter
(Figure17).
g010000
Figure17
1.Fuellter
3.Fuelline
2.Clamp
4.Loosentheclampssecuringthefuelltertothe
fuellines.
5.Removethelterfromthefuellines.
6.Installanewltertothefuellineswiththeclamps
previouslyremoved.Filteristobemountedso
thatthearrowpointstowardthecarburetor.
7.Wipeupanyspilledfuel.
ElectricalSystem
Maintenance
ServicingtheBattery
ServiceInterval:Every25hours—Checkthe
electrolytelevelandcleanthe
battery.
Every25hours—Checkthebatterycable
connections.
Every25hours
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandlead
compounds,chemicalsknownto
theStateofCaliforniatocause
cancerandreproductiveharm.Wash
handsafterhandling.
DANGER
Batteryelectrolytecontainssulfuricacid
whichisadeadlypoisonandcausessevere
burns.
•Donotdrinkelectrolyteandavoidcontact
withskin,eyes,orclothing.Wearsafety
glassestoshieldyoureyesandrubber
glovestoprotectyourhands.
•Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
Thebatteryelectrolytelevelmustbeproperly
maintainedandthetopofthebatterykeptclean.Ifthe
machineisstoredinalocationwheretemperatures
areextremelyhigh,thebatterywillrundownmore
rapidlythanifthemachineisstoredinalocation
wheretemperaturesarecool.
Maintainthecelllevelwithdistilledordemineralized
water.Donotllthecellsabovethebottomofthesplit
ringinsideeachcell.
Keepthetopofthebatterycleanbywashingit
periodicallywithabrushdippedinammoniaor
bicarbonateofsodasolution.Flushthetopsurface
withwateraftercleaning.Donotremovethellcaps
whilecleaning.
Thebatterycablesmustbetightontheterminalsto
providegoodelectricalcontact.
21