Operator's Manual

ElectricalSystem
Maintenance
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
ServicingtheBattery
Batteryvoltage:12Vwith300A(cold-cranking)at
-18°C(0°F).
Alwayskeepthebatterycleanandfullycharged.
Ifthebatteryterminalsarecorroded,cleanthem
withasolutionof4partswaterand1partbaking
soda.
Applyalightcoatingofgreasetothebattery
terminalstopreventcorrosion.
DisconnectingtheBattery
WARNING
Incorrectbatterycableroutingcoulddamage
themachineandcables,causingsparks.
Sparkscancausethebatterygassesto
explode,resultinginpersonalinjury.
Alwaysdisconnectthenegative(black)
batterycablebeforedisconnectingthe
positive(red)cable.
Alwaysreconnectthepositive(red)battery
cablebeforereconnectingthenegative
(black)cable.
Alwayskeepthebatterystrapinplaceto
protectandsecurethebattery.
WARNING
Batteryterminalsormetaltoolscouldshort
againstmetalmachinecomponents,causing
sparks.Sparkscancausethebatterygasses
toexplode,resultinginpersonalinjury.
Whenremovingorinstallingthebattery,
donotallowthebatteryterminalstotouch
anymetalpartsofthemachine.
Donotallowmetaltoolstoshortbetween
thebatteryterminalsandmetalpartsofthe
machine.
DisconnectthebatteryasshowninFigure47.
g034311
Figure47
42