Service Manual

2. Adjust float level.
A. Lightly push up float until it stops, then measure
clearance between needle valve and float lever
.
Needle valve to
float lever clearance 1.45 mm (.057 in.)
Figure 145
B. If clearance is out of specification, adjust by
bending float lever as shown.
Figure 146
3. Install ball, weight and retainer in correct sequence
and location as shown.
Retainer
Ball
Weight
Figure 147
4. Insert power needle (attached to piston valve assem-
bly) into power nozzle and install piston valve assembly
so diaphragm outer surface does not slip out from
groove.
Figure 148
Liquid Cooled Gas Engine
Page 3
76
Workman 3000/4000 Series