Operator's Manual

FuelSystem
Maintenance
InspectingFuelLinesand
Connections
ServiceInterval:Every400hours/Yearly(whichever
comesrst)
Inspectthefuellines,ttings,andclampsforsignsof
leaking,deterioration,damage,orlooseconnections.
Note:Repairanydamagedorleakingfuelsystem
componentbeforeusingthemachine.
ReplacingtheFuelFilter
ServiceInterval:Every800hours/Yearly(whichever
comesrst)
1.Raisethebedandsupportitwiththeproprod.
2.RotatethekeyswitchtotheOFFpositionand
removethekey.
3.Placeadrainpanunderthefuellter.
4.Unscrewthefuellterfromthebracket(Figure
35).
g017504
Figure35
1.Fuellter
5.Installthereplacementlterbyturningituntilthe
ltercontactsthetopofthebracket,thentighten
itanadditional3/4ofaturn.
ElectricalSystem
Maintenance
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
ServicingtheBattery
Batteryvoltage:12Vwith300A(cold-cranking)at
-18°C(0°F).
Alwayskeepthebatterycleanandfullycharged.
Ifthebatteryterminalsarecorroded,cleanthem
withasolutionof4partswaterand1partbaking
soda.
Applyalightcoatingofgreasetothebattery
terminalstopreventcorrosion.
DisconnectingtheBattery
WARNING
Incorrectbatterycableroutingcoulddamage
themachineandcables,causingsparks.
Sparkscancausethebatterygassesto
explode,resultinginpersonalinjury.
Alwaysdisconnectthenegative(black)
batterycablebeforedisconnectingthe
positive(red)cable.
Alwaysconnectthepositive(red)battery
cablebeforeconnectingthenegative
(black)cable.
Alwayskeepthebatterystrapinplaceto
protectandsecurethebattery.
34