Installation Instructions

Contactbetweennon-insulatedplatformlift
andpowerlineswillcauseelectrocution.
Electrocutionwillcauseseriouspersonal
injuryordeath.
Neveruseplatformliftnearpowerlines.
Neverallowplatformlifttotouchpower
lines.
Ifpowerlinecontactoccurs:
Lowerunitawayfromcontactifpossible.
Donottouchpowerline.
Nevertouchgroundwhiletouching
platformliftorpowerline.
Jumpclearifnecessary,withouttouching
platformliftorpowerline.
Ifoperatingplatformliftnearelectrical,high
pressureoranytypeofrotatingequipment:
Alwaysdisconnectpowertothat
equipment.
AlwaysuseOSHAapprovedlock-out
devices.
Neverusetheplatformliftduringathunder
orlightningstorm.
Lowertheplatformliftandavoidopenareas
intheeventofthreateningweather.
EmergencyLowering
1.Reachintoaccessopeningonlytoactivate
emergencyloweringvalve.
2.Pushinredknobonsolenoidvalve(Figure29)and
rotate180degreescounter-clockwisetoactivate
emergencyloweringvalve.
Contactwithmovingscissorarmscancause
personalinjury.
Standclearofscissorarmswhileplatform
ismoving.
Makesureareaisclearofbystandersbefore
loweringplatform.
Neverworkunderraisedplatformwithout
liftsafetyblocksinstalled.
Alwaysremovekeyfromliftcontrolbox
whenplatformisnotinuse.
Figure29
1.Emergencyloweringvalveknob
3.Tostopliftandreturntonormaloperation,push
buttonin,rotate180degreesclockwiseandrelease.
20