Operator's Manual

CheckingtheCoolingSystem
ServiceInterval:Beforeeachuseordaily
Coolingsystemcapacity:4qt(3.7l)
Thecoolingsystemislledwitha50/50solutionof
waterandpermanentethyleneglycolantifreeze.
1.Parkthemachineonalevelsurface.
CAUTION
Iftheenginehasbeenrunning,thepressurized,
hotcoolantcanescapeandcauseburns.
Donotopentheradiatorcapwhenthe
engineisrunning.
Allowtheenginetocoolatleast15minutes
oruntiltheradiatorcapiscoolenoughto
touchwithoutburningyourhand.
Usearagwhenopeningtheradiatorcap,
andopenthecapslowlytoallowsteamto
escape.
2.Checkthecoolantlevelonthesideofthereserve
tank(Figure18).Thecoolantshouldbeuptothe
Coldline,whenengineiscold.
Figure18
1.Reservetank
3.Coldline
2.Hotline
3.Ifcoolantislow,removethereservetankcap
andadda50/50mixtureofwaterandpermanent
ethyleneglycolantifreeze.Donotoverll.
4.Installthereservetankcap.
Checkingthe
Transaxle/HydraulicFluid
Level
ServiceInterval:Beforeeachuseordaily
ThetransaxlereservoirislledwithDexronIIIATF .
Checkthelevelbeforetheengineisrststartedand
every8hoursordaily,thereafter.Capacityofsystemis.
Transaxlereservoircapacity:7.5qt(7l).
1.Positionthevehicleonalevelsurface.
2.Cleantheareaaroundthedipstick(
Figure19).
Figure19
1.Dipstick
3.Unscrewthedipstickfromthetopofthetransaxle
andwipeitwithacleanrag.
4.Screwthedipstickintothetransaxleandensurethat
itisfullyseated.
5.Unscrewthedipstickandchecktheuidlevel.
Theuidshouldbeuptotopoftheatportion
ofthedipstick.
6.Ifthelevelislow,addenoughuidtoachievethe
properlevel.
CheckingtheHighFlow
HydraulicFluid(TCmodels
only)
ServiceInterval:Beforeeachuseordaily
Thehighowhydraulicsreservoirislledwith
approximately4USgallons(15l)ofhighquality
hydraulicuid.Checkthelevelofhydraulic
uidbeforetheengineisrststartedanddaily
thereafter.
1.Cleantheareaaroundthellerneckandthecap
ofthehydraulictank(
Figure20).Removethecap
fromthellerneck.
23