Installation Instructions

G003620
1
2
3
4
5
6
Figure35
1.Valve
4.Cabletie
2.Smallconnector
5.Relay
3.Diode
6.Squareconnector
13
InstallingtheHydraulicOiland
CheckingforLeaks
Partsneededforthisprocedure:
1Dipstick
6–3/4
gallons
(25.5
liters)
Hydraulicoil
Procedure
Thehydraulicsystemcapacityisnow6–3/4gallons.
RefertotheOperator'sManualforthecorrectoiltouse.
1.Removetheolddipstickfromthehydraulictankand
discard.
2.Slowlypourapproximately80%ofthespeciedoil
intothetank.
3.Insertthenewdipstickandcheckthehydraulicoillevel
(
Figure36).
4.SlowlyaddtheadditionaloiltobringittotheFull
mark.
Figure36
1.Hydraulictankcap3.Hydraulictank
2.Dipstick
5.Startthemachineandletitrunfor5minutes.
6.Checkforanyleaksinthesystemwithapieceof
cardboard.Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
Ifhydraulicuidisinjectedintotheskinit
mustbesurgicallyremovedwithinafew
hoursbyadoctorfamiliarwiththistype
ofinjury.Gangrenemayresultifthisis
notdone.
Keepbodyandhandsawayfrompinhole
leaksornozzlesthatejecthighpressure
hydraulicuid.
Usecardboardorpapertondhydraulic
leaks.
Safelyrelieveallpressureinthehydraulic
systembeforeperforminganyworkonthe
hydraulicsystem.
Makesureallhydraulicuidhosesand
linesareingoodconditionandallhydraulic
connectionsandttingsaretightbefore
applyingpressuretohydraulicsystem.
7.Installtheleftfrontscreentotheframe.
8.Installthefrontshroudtotheframewith4ange-head
screws.
9.Installthe4ange-headscrewssecuringtheleft-hand
wheelshroudtotheframe(
Figure37).
10.Installtheleftreartire(Figure37).
14