Removal (Fig. 2)
1. Park machine on a level surface, fully raise coring
head, stop engine and remove key from the ignition
switch.
2. Raise lock–up brackets on each side of machine and
lower coring head until it rests on brackets.
3. Remove exhaust muffler guard (see Exhaust Sys-
tem Removal in Service and Repair section of Chapter
3 – Engine).
4. Loosen fasteners that secure belt guide (item 3) to
machine.
5. Remove drive belt from engine pulley and transaxle
pulley
. Pull drive belt from machine.
Figure 3
Installation (Fig. 2)
1. Position drive belt to transaxle and engine pulleys
(.8 to 2.3 mm)
.030 to .090”
noting correct belt routing (Fig. 3).
2. Secure belt guide (item 3) to machine with fasteners
loosened during belt removal. After guide is secured,
there should be .030” to .090” (.8 to 2.3 mm) clearance
between the guide and the drive belt (Fig. 4).
3. Check and adjust drive belt tension (see Operator’s
.030 to .090”
Manual).
(.8 to 2.3 mm)
4. Install exhaust muffler guard (see Exhaust System
Installation in Service and Repair section of Chapter 3
Figure 4
– Engine).
5. Lower lock–up brackets from coring head before ma-
chine use.
Greens Aerator Page 7 – 5 Drive T
rain
Drive Train