Operator's Manual

1
Figure5
1.Batterycompartment
3.Cleanthetopofthebatteryandremovethevent
caps.
4.Carefullylleachcellwithelectrolyteuntiltheplates
arecoveredwithabout1/4inch(6mm)ofuid.
Useonlyelectrolyte(1.265SpecicGravity)toll
thebatteryinitially.
Important:Donotaddelectrolytewhilethe
batteryisinthemachine.Youcouldspillit,
causingcorrosion.
DANGER
Batteryelectrolytecontainssulfuricacidwhich
isadeadlypoisonandcausessevereburns.
Donotdrinkelectrolyteandavoidcontact
withskin,eyes,orclothing.Wearsafety
glassestoshieldyoureyesandrubbergloves
toprotectyourhands.
Fillthebatterywherecleanwaterisalways
availableforushingtheskin.
5.Allowapproximately20to30minutestoallowall
trappedgastoescapefromtheplates.Rellas
necessarytobringtheelectrolytetowithinabout1/4
inch(6mm)ofthebottomofthellwell.
6.Connecta3to4ampbatterychargertothebattery
posts.Chargethebatteryatarateof3to4amps
untilthespecicgravityis1.250orhigherandthe
temperatureisatleast60degreesF(16degreesC)
withallcellsgassingfreely.
WARNING
Chargingthebatteryproducesgassesthatcan
explode.
Neversmokenearthebatteryandkeepsparks
andamesawayfromit.
7.Whenthebatteryischarged,disconnectthecharger
fromtheelectricaloutletandbatteryposts.
Note:Afterthebatteryhasbeenactivated,add
onlydistilledwatertoreplacenormalloss,although
maintenance-freebatteriesshouldnotrequirewater
undernormaloperatingconditions.
8.Insertthebatteryintothetrayinthebattery
compartment(
Figure6)Positionthebatterysothe
terminalsaretotheoutside.
WARNING
Batteryterminalsormetaltoolscouldshort
againstmetalmachinecomponentscausing
sparks.Sparkscancausethebatterygassesto
explode,resultinginpersonalinjury.
Whenremovingorinstallingthebattery,do
notallowthebatteryterminalstotouchany
metalpartsofthemachine.
Donotallowmetaltoolstoshortbetween
thebatteryterminalsandmetalpartsofthe
machine.
9.Securethebatterytothecompartmentbasewitha
batteryrod,2holddownrods,2atwashers,and2
wingnuts(Figure6).
12