Operator's Manual

lb(28.5kg)tothemachine.Uptotwoplatescanbe
added.RefertothePartsCatalogforthesepartnumbers.
AeratorControlModule(ACM)
TheAeratorControlModuleisapottedelectronic
deviceproducedinaonesizetsallconguration.The
moduleusessolidstateandmechanicalcomponents
tomonitorandcontrolelectricalfeaturesrequiredfor
safeproductoperation.
1
Figure38
1.Aeratorcontrolmodule
Themodulemonitorsinputsincludingheadlow,head
high,transport,aerate,andgroundfollowing.The
moduleisdividedintoinputsandoutputs.Inputs
andoutputsareidentiedbygreenLEDindicators
mountedontheprintedcircuitboard.Poweris
identiedbyaredLEDindicator.
Thestartcircuitinputisenergizedby12VDC.All
otherinputsareenergizedwhenthecircuitisclosed
toground.EachinputhasanLEDthatisilluminated
whenthespeciccircuitisenergized.Usetheinput
LED’sforswitchandinputcircuittroubleshooting.
Outputcircuitsareenergizedbyanappropriatesetof
inputconditions.ThethreeoutputsincludeSVL,SVR,
andSVQ.OutputLED’smonitorrelayconditions
indicatingthepresenceofvoltageatoneofthree
specicoutputterminals.
Outputcircuitsdonotdetermineoutputdevice
integrity,soelectricaltroubleshootingincludesoutput
LEDinspectionandconventionaldeviceandwire
harnessintegritytesting.Measuredisconnected
componentimpedance,impedancethroughwire
harness(disconnectatACM),orbytemporarilytest
energizingthespeciccomponent.
TheACMdoesnotconnecttoanexternalcomputeror
handhelddevice,cannotbereprogrammed,anddoes
notrecordintermittentfaulttroubleshootingdata.
ThedecalontheACMonlyincludessymbols.Three
LEDoutputsymbolsareshownintheoutputbox.All
otherLED’sareinputs.Thechartbelowidentiesthe
symbols.
Figure39
1.On/off
7.Headlow
2.Output
8.Headhigh
3.Solenoidvalvelower9.Transport(1)
4.Solenoidvalveraise10.Aerate(4)
5.Solenoidvalvequick11.Groundfollowing
6.Input
12.OKtolower
HerearethelogicaltroubleshootingstepsfortheACM
device.
1.Determinetheoutputfaultyouaretryingtoresolve.
2.MovethekeyswitchtotheOnpositionandensure
theredpowerLEDisilluminated.
3.MoveallinputswitchestoensureallLED’schange
state.
4.Positioninputdevicesattheappropriatepositionto
achievetheappropriateoutput.
5.IfspecicoutputLEDisilluminatedwithout
appropriateoutputfunction,checkoutputharness,
connections,andcomponent.Repairasrequired.
6.IfspecicoutputLEDisnotilluminated,check
bothfuses.
7.IfspecicoutputLEDisnotilluminatedandinputs
areinappropriatecondition,installnewACMand
determineiffaultdisappears.