Service Bulletin

Page 2 of 2
4) Verify the cable/linkage is free by pushing and pulling while disconnected from the load:
a. If cable/linkage moves freely, go to step 5.
b. If cable/linkage binds or sticks, replace the cable/linkage.
5) Remove the dampener (if applicable) and retest.
a. If unit stops normally, replace dampener.
b. If unit still takes too long to stop, repair hydrostat.
For additional information or assistance, contact your local authorized Toro Commercial Products
Distributor.