Operator's Manual

Greasing Bearings and
Bushings
The main working bearings of the aerator are sealed
for life and require no maintenance or lubrication.
This drastically reduces the maintenance required and
eliminates the risk of grease or oil being dropped onto
the turf.
There are grease fittings that must be lubricated with
an SAE multi-purpose, high -temperature grease with
high pressure (EP) performance or SAE multi-purpose
lithium base grease.
The lubrication intervals and points are:
LUBRICATE DAILY—PTO shaft (3) (Fig. 23).
Figure 23
LUBRICATE WEEKLY—Roller bearings (2) (Fig.
24), depth jacks (2) (Fig. 25), drive shaft bearings (2)
(Fig. 26).
Figure 24
Figure 25
Figure 26
Gearbox Lubrication
The gearbox is filled with 85/140 gear oil or
equivalent.
Check gearbox oil level every 6 months or 100 hours.
1. Remove the check plug at the rear of the gearbox.
2. Make sure oil is up to bottom of the plug hole in
the gearbox.
3. If oil level is low, remove fill plug on top of the
gearbox and replenish oil as required.
4. Install the plug.
25
Maintenance