Operator's Manual

3
InstallingtheSpectrometers
NoPartsRequired
Procedure
Note:Thereisaleft-handandright-handspectrometer.To
ensurethecorrectinstallation,themountingbracketshave
specicholespacingsformountingthespectrometers.
1.Removethespectrometersfromthepacking.
2.Matchthemountingholesineachspectrometerwith
theholesinthemachineframe.
3.Installthespectrometerstothemachinewith4bolts
(3/8x3/4inch)and4angenuts(3/8inch)(
Figure3).
Figure3
1.Bolt3.Locknut
2.Spectrometer
4
RemovingtheTine-Alignment
Tool
NoPartsRequired
Procedure
WARNING
Thesensorholdercanrotateupsuddenlyandinjure
someone.
Ensurethesensorholderisheldandgradually
rotatedintopositionwhenremovingthe
tine-alignmenttool.
1.Whileholdingdownthesensorholder,removethe
boltholdingthesensorholdertothetine-alignment
tool(Figure4).
g022019
3
2
1
Figure4
Senorholdertopview
1.Bolt
3.Sensorholder
2.Sensor
2.Graduallyrotatethesensorholderupintotheoperating
position.
3.Removethe2nutsandboltsholdingthealignment
tooltotheframe.Savethehardwareforfutureuse.
4.Removethealignmenttool(Figure5).
7