Installation Instructions

1
All Rights Reserved
Printed in the USA
W 2005 by The Toro Company
8111 Lyndale Avenue South
Bloomington, MN 55420-1196
Cartridge Valve Kit
Reelmaster
)
5000 & 6000 Series
Part No. 110–0000
Form No. 3353–371 Rev A
Installation Instructions
1. Loosen the nuts securing the (2) solenoid coils to the
top of the manifold as shown in figures 1 & 2.
Figure 1 shows the Reelmaster 5200 & 5400 and
figure 2 shows the Reelmaster 5500, 6500 & 6700.
1
1
Reelmaster 5200 & 5400
Figure 1
1. Solenoid coils (2)
1
1
Reelmaster 5500, 6500 & 6700
Figure 2
1. Solenoid coils (2)
2. Unplug the solenoid coil wires from the wire harness
connectors. Remove and discard the coils.
3. Loosen and remove both the cartridge valves from the
manifold (Fig. 3). Make sure all O–rings are removed.
1
Figure 3
1. Cartridge valve
4. Thread the new cartridge valves w/O–rings into the
manifold. Tighten the valves to 45 ft–lbs.
5. Install the new solenoid coils onto the valves. Install
the O–rings and retaining nuts. Tighten the retaining
nuts to 2 to 5 ft–lbs.
6. Connect the solenoid coil wires.