Installation Instructions

FormNo.3361-781RevA
ReplacementFlowMeterKit
forMulti-Pro
®
1100TurfSprayer
ModelNo.117-5802
InstallationInstructions
InstallingtheFlowmeter
Parkthemachineonalevelsurfaceandengagethe
parkingbrake.TurntheignitionkeytoOfftostopthe
engine.Removethekey.
Accidentalstartingoftheenginecouldseriously
injureyouorotherbystanders.
Removethekeyfromtheignitionswitchbefore
youdoanymaintenance.
1.Locatetheexistingowmeterandobservethe
directionoftheowarrowonthemeter.Disconnect
theowmeterfromthemachinewiringharness.
2.Removetheclampssecuringthehosestotheexisting
owmeterandthenremovetheowmeter.Discard
theowmeter.
Note:Takethistimetoinspectthehosesaround
theworkareaforanydamage,cracks,leaksorother
wear.Replaceanydamagedparts.
3.AssemblethenewowmeterasshowninFigure1
G010154
1
2
3
4
5
Figure1
1.Flowmeterbody
4.Clamp
2.Gasket
5.Flowarrow
3.Barb
Note:Thereisanarrowonthemeterbodythat
describestheowdirectiontoaidininstallation.
4.Lightlysoaporlubricatethebarbsoftheassembled
owmeterandthehosesonthemachinetoease
installation.
5.Installtheowmeterinthesameoworientationas
thepreviousmeter(Figure2).Usetheowarrow
onthemeterbodytoverifyitispointinginthe
samedirectionasthepreviousmeter.
G010155
1
2
1
3
4
Figure2
1.Flowarrow
3.Existingowmeter
2.Newowmeter
4.Existinghosesandclamps
6.Usetheexistinghoseclampstosecurethemeter.
7.Connecttheowmetertotheexistingwiring
harnessonthemachine.
8.RefertotheOperator’sManualandliterature
accompanyingtheowmeterforpropercalibration
ofthemeterandspraysystem.
©2008—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA.
AllRightsReserved

Summary of content (1 pages)