Installation Instructions
FormNo.3372-980RevA
ControllerReplacementKit
2010-11ProForceDebrisBlower
ModelNo.121-2812
InstallationInstructions
Installation
1.Disconnectthenegativebatterycablerstandthen
disconnectthepositivebatterycable.
2.Disconnectthewireharnessconnectorsfromthe
receiver(
Figure1).
1
2
g017839
Figure1
1.Receiver2.Wireharnessconnectors
3.Removethe(3)screwsandnutssecuringthereceiver
totheblowerframe(Figure1).Removethereceiver.
4.Positionthenewreceiverontotheframealigningit’s
rightmountingholewiththeupperrightmounting
holeusedtomounttheoldreceiver(
Figure2).
g018294
1
Figure2
1.Receiver
5.Usingtheleftholeinthenewreceiverasatemplate,
locate,markanddrilla.281inch(.713cm)diameter
holeintheframe(Figure2).Makesurethewireless
controllerislevel.
Note:Theholes,describedinsteps8and10,may
alsobedrilledatthistime,ifdesired.
6.Mountthenewreceivertothefrontoftheframe
with(2)1/4x1–1/4inchscrewsand1/4inchange
nuts(
Figure3).