Operator's Manual

ChargingtheBattery
ServiceInterval:Every25hours
Electric-startmodelsonly
Warning
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandleadcompounds,
chemicalsknowntotheStateofCalifornia
tocausecancerandreproductiveharm.
Washhandsafterhandling.
Chargethebatteryfor24hoursinitially,thenmonthly
(every25starts)orasneeded.Alwaysusethecharger
inashelteredareaandchargethebatteryatroom
temperature(70°or22°C)wheneverpossible.
1.Connectthechargertothemowerwireharness
locatedbelowtheignitionkey(Figure26).
Figure26
2.Plugthechargerintoawalloutlet.
Note:Whenthebatterynolongerholdsacharge,
recycleordisposeofthelead-acidbatteryaccording
tolocalcodes.
Note:Yourbatterychargermayhaveatwo-colorLED
displaythatindicatesthefollowingstatesofcharging:
Aredlightindicatesthatthechargerischargingthe
battery.
Agreenlightindicatesthatthechargerisfully
chargedorthechargerisdisconnectedfromthe
battery.
Aashinglightthatalternatesbetweenredandgreen
indicatesthatthebatteryisnearlyfullycharged.This
statelastsonlyafewminutesuntilthebatteryisfully
charged.
ReplacingtheFuse
Electric-startmodelsonly
Ifthebatterydoesnotchargeortheenginedoesnotrun
withtheelectricstarter,thefusemaybeblown.Replace
itwitha40-ampplug-intypefuse.RefertoInstallingthe
FuseintheSetupsection.
ReplacingtheBlade
ServiceInterval:Yearly
Important:
Y ou will need a torque wr ench to install
the blade pr oper l y
.Ifyoudonothaveatorque
wrenchorareuncomfortableperformingthis
procedure,contactanAuthorizedServiceDealer.
Examinethebladewheneveryourunoutofgasoline.If
thebladeisdamagedorcracked,replaceitimmediately.
Ifthebladeedgeisdullornicked,haveitsharpenedand
balanced,orreplaceit.
Thebladeissharp;contactingthebladecan
resultinseriouspersonalinjury.
Weargloveswhenservicingtheblade.
1.RefertoPreparingforMaintenance.
2.Tipthemowerontoitssidewiththeairlterup.
3.Useablockofwoodtoholdthebladesteady
(Figure27).
16