Specifying Information—220G Brass Series
220G-27-0XXX
Type Body Style Size Optional
220G 27 OX XX
220G—220G Brass Series Valve
27—NPT, Pressure-regulated (5–100 PSI) 4—1"
5—1
1
4
"
6—1
1
2
"
8—2"
DL—Latching Solenoid for 2-wire GDC Systems
EEffluent
Example: A 1" NPT pressure-regulated, 220G Brass Series Valve with 60 Hz solenoid, would be specified as: 220G-27-04
220G Brass Series Friction Loss Data
Model Type
GPM Flow
5 10 15 20 30 40 50 60 70 80 100 120 150 170 180
1" Electric
2.0 2.5 1.5 2.5 5.5 8.9
1
1
/4" Electric
4.4 4.7 5.1 5.5 5.8 7.2
1
1
/2" Electric
3.9 4.2 4.6 4.9 5.2 5.5 7.2
2" Electric
1.0 2.0 2.0 2.5 3.0 3.5 6.0 7.5 10.0 12.0 14.0
Notes: For optimum performance when designing a system, calculate total friction loss to ensure sufficient downstream pressure.
For optimum regulation performance, size regulating valves toward the higher flow ranges.
Flow rates are recommended not to exceed 5 psi loss.
Valve Wire Sizing Chart
Maximum One-way Distance (in ft.) Between Controller
and Valve Using Spike-Guard
Solenoid*
Ground Wire
Control Wire
18 16 14 12 10 8 6
18 2040 2520 2940 3280 3540 3720 3860
16 2520 3260 4000 4660 5220 5620 5920
14 2940 4000 5180 6360 7420 8300 8960
12 3280 4660 6360 8240 10100 11800 13180
10 3540 5220 7420 10100 13180 16060 18770
8 3720 5260 8300 11800 16060 20800 25540
6 3860 5960 8960 13180 18700 25540 33080
* Solenoid Model: 24 V ac Pressure: 150 psi
Voltage Drop: 4 V Minimum Operating Voltage: 20 V Amperage (peak) 0.12 A
Dimensions
• 1” – 5 ¼” H x 5” W
• 1 ¼” – 6 ½” H x 6” W
• 1 ½” - 6 ½” H x 6” W
• 2” – 7 ½” H x 7” W
Operating Specifications
• Flow Range:
– 1” – 5 to 40 GPM – 1 ¼” – 20 to 100 GPM
– 1 ½” – 20 to 130 GPM – 2” – 30 to 180 GPM
• Operating Pressure (220 psi maximum pressure rating):
– Electric – 10 to 220 psi
• Pressure regulating:
– Outlet: 5 to 100 psi ± 3 psi
• Inlet: 10 to 220 psi
• Minimum pressure differential (between inlet and outlet)
for pressure regulation: 10 psi
• Burst pressure safety rating: 750 psi
• Body style:
– Globe valve – 1”, 1 ¼”, 1 ½”, 2” female threads
• Spike Guard™ Solenoid: 24 VAC (50/60 Hz) Standard
– Inrush: 60 Hz: 0.12 amps
– Holding: 60 Hz: 0.1 amps
Warranty
• Five years
Additional Features
• Diaphragm stem guide
• Ingot brass and stainless steel construction
• Pressure regulates in electric and manual modes,
serviceable under pressure
• Forward-flow design for more precise regulation
• Standard, built-in Schrader-type valve for downstream
pressure verification
• Anti-vandal dust cap on pressure-regulating models
• No external tubing
• External manual bleed for system flushing
• Manual flow control: adjustable to zero flow
• Stainless steel diaphragm support ring for minimum wear
• Stainless steel solenoid seat for longer life and positive shutoff
• Low-power requirement for longer wire runs