Operator's Manual

Maintenance
26
4. If the traction unit veers to the right, loosen the
the left jam nut and adjust the tracking set screw
on the front of the traction control
(Fig. 22).
m–4664
1
1
Figure 22
1. Jam nut and set screw
5. Repeat steps 1 through 4 until the traction unit
drives straight in the full forward position.
Adjusting the Auxiliary Hydraulics Lever,
Reverse Flow Stop
In the reverse flow slot of the auxiliary hydraulics
lever assembly is a bolt that keeps the lever from
going too far into the slot into a detent position (i.e., a
position that allows it to stay in the slot without being
held by the operator). If the lever goes into a detent
position, or if the reverse flow hydraulics speed is
slow, adjust the bolt using the following procedure:
1. Stop the engine and remove the key.
2. Remove the three bolts securing the left control
panel cover and remove the cover (Fig. 23).
3. Loosen the jam nut on the adjustment bolt
(Fig. 23).
m–4777
2
3
1
Figure 23
1. Left control panel cover
2. Jam nut
3. Adjustment bolt
4. Turn the adjustment bolt clockwise until the
lever slips into a detent position.
5. Slowly turn the adjustment bolt
counter-clockwise until the lever slips out of a
detent position.
6. Hold the adjustment bolt and tighten the jam nut.
7. Install the left panel cover.
Servicing the Air Cleaner
Foam Pre-filter: Clean every 25 operating hours.
Paper Filter: Clean every 25 operating hours.
Replace after every 100 operating hours.
Note: Service the air cleaner more frequently
if operating conditions are extremely
dusty or sandy.
Removing the Foam and Paper Filters
1. Lower the loader arms, stop the engine, and
remove the key.