Service Manual

ATTACHMENTS
10-24 TX 413 Service Manual
Rev. 001
Fig 084 CLR DSC-0243
3. Clean grease from nose roller to expose the retain-
ing ring. Remove with snap ring pliers (Fig. 084).
Note: The nose roller bearing is removed from the
same side of the nose roller as the retaining
ring. Make sure the bearing rotates freely.
Replace if necessary. Press the bearing back
into the nose roller from the retaining ring
side until the bearing is seated (Fig. 085).
Fig 085 CLR DSC-0244
Fig 086 CLR DSC-0244
4. Block the nose roller up on a press so the bearing
has room to come out. Press the bearing out of the
nose roller (Fig. 086 and Fig. 087).
Fig 087 CLR DSC-0245