5.TurnthekeyinthekeyswitchtotheONposition.
Theelectricfuelpumpbeginsoperation,thereby
forcingairoutaroundtheair-bleedscrew.Leave
thekeyintheONpositionuntilasolidstreamof
fuelowsoutaroundthescrew.
6.TightenthescrewandturnthekeytotheOFF
position.
Note:Theengineshouldstartaftertheabove
bleedingproceduresarefollowed.However,ifengine
doesnotstart,airmaybetrappedbetweeninjection
pumpandinjectors;contactyourAuthorizedService
Dealer.
DrainingtheFuelTank(s)
ServiceInterval:Every2years
HaveanAuthorizedServiceDealerdrainandclean
thefueltank(s).
ElectricalSystem
Maintenance
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
Batteryacidispoisonousandcancauseburns.
Avoidcontactwithskin,eyes,andclothing.Protect
yourface,eyes,andclothingwhenworkingwitha
battery.
Batterygasescanexplode.Keepcigarettes,
sparks,andamesawayfromthebattery.
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandlead
compounds,chemicalsknownto
theStateofCaliforniatocause
cancerandreproductiveharm.Wash
handsafterhandling.