Operator's Manual

Important:Pumpgreaseinslowlyandcarefully
topreventdamagetothebearingseals.
EngineMaintenance
ServicingtheAirCleaner
ServiceInterval:Beforeeachuseordaily
Thecycloneairltercollectsthelargestcontaminantparticles,
whichcollectinthecontainer.Whenyoucanseealayerof
dirtatthebottomofthecontainer,cleanthecyclonehousing,
airchannels,andairintakescreen.
ServicingtheCycloneAirFilter
ServiceInterval:Every50hours
1.Removethe3screwsholdingthecyclonehousing.
2.Removethehousingwiththeairintakescreenand
removetheairchannels.
Figure14
1.Cyclonehousing
3.Airchannels
2.Screw4.Cyclonehousingwithair
intakescreen
Note:Theairchannelsmayremainintheupper
portionorfollowalongwiththehousingwhen
removed.
3.Cleanthecomponents.Usewater,detergentanda
brush.Drycarefully.
4.Placetheairchannelsinthecyclonehousing.
5.Insertcyclonehousingintopositionandmakesureit
tsintheupperportion.Donotuseforce;alignitin
placebeforettingthescrews.
ReplacingtheAirFilter
ServiceInterval:Every200hours
Iftheengineislowonpower,producesblacksmokeorruns
unevenly,theairltermaybeclogged.
1.Removethewingnutandliftoffthecyclonelterwith
theairltercowling(Figure15).
13