Operator's Manual

Table Of Contents
FuelSystem
Maintenance
CleaningtheFuel-Sediment
Cup
ServiceInterval:Every100hours/Every6months
(whichevercomesrst)—Cleanthe
fuel-sedimentcup.
Yearlyorbeforestorage—Cleanthe
fuel-sedimentcup.
Underneaththefuelvalveisasedimentcuptocatch
dirtinthefuel.
1.Parkthemachineonalevelsurfaceandshut
offtheengine.
2.Allowtheenginetocool.
3.Disconnectthewirefromthesparkplug;referto
DisconnectingtheSpark-plugWire(page18).
4.MovetheleverofthefuelvalvetotheOFF
position,allthewaytotheleft(Figure30).
5.Unscrewthefuel-sedimentcup(Figure30).
6.RemoveandretainthefuellterandO-ring
(Figure30).
Note:DonotcleantheO-ringinsolvent.
g019333
Figure30
1.Fuelvalve—OFFposition3.Fuellter
2.O-ring
4.Fuel-sedimentcup
7.Cleanthefuellterandsedimentcupusinga
nonammablesolvent,anddryitcarefully.
8.WipetheO-ringwithaclean,drycloth.
9.Installthefuellterinthebottomofthe
carburetor(Figure30).
10.AligntheO-ringintothegrooveinthesediment
cupandinstallthesedimentcuptothefuel-valve
housing.
11.MovetheleverofthefuelvalvetotheON
position(allthewaytotheright)andcheckfor
leaks.Ifitleaks,replacetheO-ring.
24