Service Manual

FUEL SYSTEM 3-17
Air Cleaner
Element Removal
Refer to Air Element Removal in the Periodic Maintenance Chapter
(2nd chapter).
Element Installation
Refer to Air Element Instalation in the Periodic Maintenance Chapter
(2nd chapter).
Element Cleaning and Inspection
Refer to Air Element Cleaning and Inspection in the Periodic Mainte-
nance Chapter (2nd chapter).
Cleaner Body Removal
Remove the elements (see Periodic Maintenance chapter).
Remove the cleaner body mounting bolts [A] and holder plate nuts
[B].
Pull the breather tube [A] off the pipe at the back of the body, and
remove the cleaner body [B].
Cleaner Body Installation
Connect the breather tube from the crankcase to the pipe at the back
of the cleaner body.
Tighten the holder plate nuts and cleaner body mounting bolts.
Torque - Holder Plate Nuts: 5.9 N
1
m (0.60 kg
1
m, 52 in
1
lb)
Cleaner Body Mounting Bolts 5.9 N
1
m (0.60 kg
1
m, 52 in
1
lb)
Housing (Case and Body) Inspection
Refer to Air Cleaner Housing (Case and Body) Inspection in the
Periodic Maintenance Chapter (2nd chaper).