Operator's Manual

ReplacingtheFuelFilter
ServiceInterval:Every200hours
Neverinstalladirtylterifitisremovedfromthefuel
line.
Note:Notehowthefuellterisinstalledinorderto
installthenewltercorrectly.
Note:Wipeupanyspilledfuel.
1.Parkthemachineonalevelsurface,engagethe
parkingbrake,andlowerthehydrauliclift.
2.Shutofftheengineandremovethekey.
3.Turnthefuelshutoffvalvetotheclosedposition
(Figure38).
4.Squeezetheendsofthehoseclampstogether
andslidethemawayfromthelter(Figure39).
g001468
Figure39
1.Hoseclamp3.Filter
2.Fuelline
5.Removethelterfromthefuellines.
6.Installanewlterandmovethehoseclamps
closetothelter.
7.Turnthefuelshutoffvalvetotheopenposition
(Figure38).
8.Checkforfuelleaksandrepairifneeded.
9.Wipeupanyspilledfuel.
ElectricalSystem
Maintenance
ServicingtheBattery
Electric-StartMachinesOnly
ServiceInterval:Every25hours—Checkthebattery
electrolytelevel.
Alwayskeepthebatterycleanandfullycharged.Use
apapertoweltocleanthebatterycase.Ifthebattery
terminalsarecorroded,cleanthemwithasolutionof
4partswaterand1partbakingsoda.Applyalight
coatingofgreasetothebatteryterminalstoreduce
corrosion.
Voltage:12Vwith300A(coldcranking)at-18°C
(0°F).
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandlead
compounds,chemicalsknownto
theStateofCaliforniatocause
cancerandreproductiveharm.Wash
handsafterhandling.
WARNING
Incorrectbatterycableroutingcoulddamage
themachineandcables,causingsparks.
Sparkscancausethebatterygassesto
explode,resultinginpersonalinjury.
Alwaysdisconnectthenegative(black)
cablebeforedisconnectingthepositive
(red)cable.
Alwaysconnectthepositive(red)cable
beforeconnectingthenegative(black)
cable.
31