Operator's Manual

AdjustingtheTraction-Control
NeutralPosition
Ifthemachinecreepsforwardorbackwardwhen
thetractioncontrolisinneutralandthemachineis
warm,youmayneedtoadjustthereturn-to-neutral
mechanismonthepumps;contactyourAuthorized
ServiceDealer.
AdjustingtheTraction-Control
ForwardPosition
Ifthemachinedoesnotdrivestraightwhenyouhold
thetractioncontrolforwardagainstthereferencebar,
completethefollowingprocedure:
1.Drivethemachinewiththetractioncontrol
againstthereferencebar,notingwhichdirection
themachineveers.
2.Releasethetractioncontrol.
3.Ifthemachineveerstotheleft,loosentheright
jamnutandadjustthetrackingsetscrewonthe
frontofthetractioncontrol(Figure55).
4.Ifthemachineveerstotheright,loosentheleft
jamnutandadjustthetrackingsetscrewonthe
frontofthetractioncontrol(Figure55).
g004194
Figure55
1.Setscrew3.Stop
2.Jamnut
5.Repeattheprocedureuntilthemachinedrives
straightinthefullforwardposition.
Important:Ensurethatthesetscrewstouch
thestopsinthefullforwardpositiontoavoid
overstrokingthehydraulicpumps.
HydraulicSystem
Maintenance
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjected
intotheskinmustbesurgicallyremoved
withinafewhoursbyadoctorfamiliarwith
thisformofinjuryorgangrenemayresult.
Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthatejecthigh
pressurehydraulicuid.
Usecardboardorpapertondhydraulic
leaks,neveruseyourhands.
HydraulicFluid
Specications
Every1,500hours/Every2years(whichever
comesrst)—Replaceallmovinghydraulic
hoses.
HydraulicTankCapacity:23L(6USgallons)
Useonly1ofthefollowinguidsinthehydraulic
system:
ToroPremiumTransmission/HydraulicTractor
Fluid(refertoyourAuthorizedT oroDealerfor
moreinformation)
ToroPremiumAllSeasonHydraulicFluid
(refertoyourAuthorizedToroDealerformore
information)
IfeitheroftheaboveT orouidsarenotavailable,
youmayuseanotherUniversalTractor
HydraulicFluid(UTHF),buttheymustbeonly
conventional,petroleum-basedproducts.The
specicationsmustfallwithinthelistedrangefor
allthefollowingmaterialpropertiesandtheuid
shouldmeetthelistedindustrystandards.Check
withyourhydraulicuidsuppliertodetermineifthe
uidmeetsthesespecications.
Note:T orowillnotassumeresponsibilityfor
damagecausedbyimpropersubstitutions,souse
onlyproductsfromreputablemanufacturerswho
willstandbehindtheirrecommendations.
MaterialProperties
cStat40°C:55to62 Viscosity,ASTMD445
cStat100°C:9.1to9.8
Viscosityindex,ASTMD2270
140to152
PourPoint,ASTMD97-37to-43°C(-35to-46°F)
39