Operator's Manual

ChargingtheNitrogen
ServiceInterval:Every500hours—Checkthenitrogen
chargeintheaccumulator.
Insidethebreakerisanaccumulator,achamberofpressurized
nitrogen.Afterseveralhoursofusethepressuremay
decrease,reducingtheperformanceofthebreaker.
Strongvibrationsintheauxiliaryhydraulichosesareasign
thepressureisdroppinginthechamber.Ifthisshould
happen,bringthebreakertoyourAuthorizedToroDealer
tobecharged.
WARNING
Withinthebreakerisachambercontaining
pressurizednitrogen,whichundertheright
circumstancescouldexplode,injuringorkilling
youorbystanders.
Donottakeapartthebodyofthebreaker.
Donotattempttochargethechamberyourself.
AlwaystakethebreakertoanAuthorizedToro
Dealerforcharging.
Ensurethatthebreakerischargedonlywith
nitrogen.Othergasescanexplode.
Donotshipthechargedbreakerviaairfreight.
Storage
1.Washtheattachmentwithmilddetergentandwater
toremovedirtandgrime.
2.Greasethebit.
3.Checkandtightenallbolts,nuts,andscrews.
4.Inspectallmountingpins,holes,thelowerbushing,roll
pins,andthebit-retainingpin.Repairorreplaceany
partthatisdamagedorworn.
5.Inspectallhydraulicttingsandhosesforleaks.Repair
orreplaceanyttingsorhosesthatleak.
WARNING
Hydraulicuidescapingunderpressure
canpenetrateskinandcauseinjury.Fluid
accidentallyinjectedintotheskinmustbe
surgicallyremovedwithinafewhoursbya
doctorfamiliarwiththisformofinjuryor
gangrenemayresult.
Keepbodyandhandsawayfrompinhole
leaksornozzlesthatejecthighpressure
hydraulicuid.
Usecardboardorpapertondhydraulic
leaks;neveruseyourhands.
6.Paintallscratchedorbaremetalsurfaces.Paintis
availablefromyourAuthorizedServiceDealer.
7.Storethebreakerinaverticalpositioninaclean,dry
garageorstoragearea.Coverittoprotectitandkeepit
clean.
Important:Ifyouarestoringthebreakerformore
thanamonth,storeitverticallytoavoiddamaging
O-ringsandsealsinsidethebreaker.