7-20 CAMSHAFT/CRANKSHAFT
Crankshaft, Connecting Rod
Crankshaft Main Journal/Wear
Measure both main journals at several points around the
journal circumference.
If the journal diameter is less than the service limit, re-
place the crankshaft with a new one.
Crankshaft Journal Diameter
Service Limit:
PTO Side [A] 39.90 mm (1.571 in.)