Service Manual
3-38 FUEL SYSTEM
Air Cleaner
•
Remove:
Bolts [A]
Bracket [B]
Air Cleaner Body and Bracket Installation
FX Models
•
Install the air cleaner bracket [A].
•
Tighten:
Torque - Air Cleaner Bracket Mounting Bolts [B]: 5.9 N·m
(0.60 kgf·m, 52 in·lb)
•
Set the air cleaner body [A] onto the lower bracket so that
the air inlet duct [B] is faci
ng upward.
•
Install the inlet hose [C], and tighten the clamp [D].
•
Install the upper bracket [E].
•
Tighten:
Torque - Air Cleaner Holder Bracket Bolts [F]: 5.9 N·m (0.60
kgf·m, 52 in·lb)
Air Cleaner Housing (Cap and Body) Inspection
FX Models
•
Refer to the Air Cleaner Housing (Cap and Body) Inspec-
tion in the Periodic Maintenance chapter.