7-12 CAMSHAFT/CRANKSHAFT
Breather
Breather Valve Removal
Remove:
Stator Coil (see Flywheel and Stator Coil Removal in the
Electrical System chapter)
Unscrew the bolts [A] and remove the clamps [B].
Remove the breather chamber cover [C] and gasket.
Remove:
Breather Pipe [A] (see Breather Pipe Removal)
Screw [B]
Back Plate [C]
Reed Valve [D]
Breather Valve Installation
Align center of the valve sea
t with center of the reed valve
and back plate.
Tighten:
Torque - Breather Valve Mounting Screws: 2.0 N·m (0.20
kgf·m, 18 in·lb)
Be sure the drain hole [A] on the breather chamber does
not accumulate with slugs.
Replace the breather chamber cover gasket with a new
one.
Install:
Breather Pipe (see Breather Pipe Installation)
Gasket
Breather Chamber Cover [A]
Clamps [B]
Tighten:
Torque - Breather Chamber Cover Bolts [C]: 5.9 m (0.60
kgf·m, 52 in·lb)
Install the removed parts (see appropriate chapters).