9-16 ELECTRICAL SYSTEM
Charging System
Regulator Installation
FX Models
Install the regulator [A].
Tighten the regulator mounting screws [B].
Apply dielectric grease to the regulator terminals [C].
Connect the stator coil lead connector [D].
FS Models
Install:
Regulator [A]
Ground Lead [B]
Tighten the regulator mounting screws [C].
Apply dielectric grease to the regulator terminals [D].
Connect the stator coil lead connector [E].
Regulator Resistance
FS and FX Models
Remove the regulator (see Regulator Removal).
Set the KAWASAKI Hand Tester selector switch to the R
× 100 position.
Connect the test leads to the points shown on the chart
and read the resistance.
(Without Charging Monitor Type …3 Blades)
+
A B C D
A
B
0
C
0
D
over than
1M
over than
1M
over than
1M
NOTE
Resistance value may vary with individual meters.
If the resistance is not as specified, replace the regulator
with a new one.