Operator's Manual

ChangingtheHydraulic-uidReturn
Filter
ServiceInterval:Every500hours/Every6months
(whichevercomesrst)
1.Parkthemachineonalevelsurface,stoptheengine,
andremovetheignitionkey.
2.Openthefronthood;refertoOpeningtheFront
Hood(page72).
3.Cleantheareaaroundthellerneckandcapofthe
hydraulictank.
4.Openthehydraulic-tankcap(Figure145).
Figure145
1.Hydraulic-tankcap
5.Discardtheoldhydraulic-uidreturnlter.
6.Installanewhydraulic-uidreturnlter.
ChangingtheHydraulic-pressureFilter
ServiceInterval:Every500hours/Every6months
(whichevercomesrst)
1.Parkthemachineonalevelsurface,stoptheengine,
andremovetheignitionkey.
2.Openthefronthood;refertoOpeningtheFront
Hood(page72).
3.Placeadrainpanunderthelter.
4.Usingalterwrench,removethehydraulic-pressure
lter(Figure146).
Figure146
1.Hydraulic-pressurelter
5.Discardtheoldlter.
6.Applyathinlayerofhydraulicoiltotheo-ringofthe
lter.
7.Installandtightenthenewlterwithalterwrench.
8.Starttheengine,letitrunidleforapproximately
1minute,thencheckforleaksaroundthe
hydraulic-pressurelter.
ChangingtheHydraulicFluid
ServiceInterval:Every1,000hours/Yearly(whichever
comesrst)
Important:Iftheuidbecomescontaminated,contact
yourAuthorizedToroDealer,becausethesystemmust
beushed.Contaminateduidlooksmilkyorblack
whencomparedtocleanoil.
Important:Useofanyotherltermayvoidthewarranty
onsomecomponents.
1.Parkthemachineonalevelsurface,stoptheengine,
andremovetheignitionkey.
2.Openthefronthood;refertoOpeningtheFront
Hood(page72).
3.Raisethemachineusingproperequipment.
98