AdjustingtheTensionoftheBelt
1.Movethemachinetoalevelsurface,shutoff
theengine,andremovethekey.
2.Openthefronthood.
3.Loosenthenutandboltatthepivotpointforthe
alternator(Figure111).
g021648
Figure111
1.Adjustmentbolt
3.Alternator
2.Nut(alternatorpivotpoint)4.Bolt(alternatorpivotpoint)
4.Loosentheadjustmentboltonthealternator
(Figure111).
5.Movethealternatorawayfromtheengineto
increasethebelttension;movethealternator
towardtheenginetodecreasethebelttension
(Figure111).
6.Tightenthealternatoradjustmentbolt(Figure
111).
7.Checkthetensionofthebelt;refertoChecking
theBeltTension(page89).
8.Ifthebelttensioniscorrect,tightenthenutand
boltatthepivotpointforthealternator(Figure
111);otherwiserepeatsteps4through7.
HydraulicSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
ServicingtheHydraulic
Fluid
Thehydraulicreservoirislledatthefactorywith
approximately102L(27USgallons)ofhigh-quality
hydraulicuid.Checkthelevelofthehydraulic
uidbeforetheengineisrststartedanddaily
thereafter.Therecommendedreplacementuid
follows:
ToroPremiumAllSeasonHydraulicFluid
(Availablein5gallonpailsor55gallondrums.Contact
yourAuthorizedServiceDealerforpartnumbers.)
Alternateuids:IftheTorouidisnotavailable,other
uidsmaybeusedprovidedtheymeetallthefollowing
materialpropertiesandindustryspecications.Wedo
notrecommendtheuseofsyntheticuid.Consultwith
yourlubricantdealertoidentifyasatisfactoryproduct.
Note:Torowillnotassumeresponsibilityfordamage
causedbyimpropersubstitutions,souseonly
productsfromreputablemanufacturerswhowillstand
behindtheirrecommendation.
HighViscosityIndex/LowPourPoint
Anti-wearHydraulicFluid,ISOVG46
MaterialProperties:
42.2cStat40°C(104°F)
Viscosity,ASTMD445
7.8cStat100°C(212°F)
ViscosityIndexASTM
D2270
158
90