Operator's Manual

A.Opentheller-neckcap.
B.Filltheradiatorwithcleanwater(Figure110).
Figure110
1.Fillerneck
3.Cleanwater
2.Funnel
C.Closetheller-neckcap.
D.Operatetheenginefor5minutesoruntilthe
coolanttemperatureindicates82°C(180°F),and
thenstoptheengine.
CAUTION
Thewaterishotandcancauseburns.
Stayawayfromthedischargeendofthe
coolantdrainplug.
E.Openthedrainpluganddrainthewaterintoa
drainpan.
F.Cleanthethreadsonthedrainplugandapply3
layersofPTFEsealingtape.
G.Ifthewaterdrainedfromtheradiatorisdirty,
performsteps3-Athrough3-Euntilthewater
drainedfromtheradiatorisclean.
H.Closethedrainplug(Figure108).
FillingtheSystemwithCoolant
Important:Youmustllthecoolingsystemproperlyto
preventairlocksinthecoolingpassages.Failingtovent
thecoolingsystemproperlycanseverelydamagethe
coolingsystemandengine.
Important:Useamixtureof50%ethyleneglycoland
50%watermixtureorequivalentinthemachine.The
lowestambientoperatingtemperatureforthismixture
isabove-37°C(-34°F).Iftheambienttemperatureis
lower,adjustthemixture.Useamixtureofethylene
glycolandwaterorequivalentinthemachineallyear.
1.Parkthemachineonalevelsurface,stoptheengine,
andremovetheignitionkey.
2.Removetheboltsfromthecoolant-accesscover
betweenthefronthoodandtherearcover.
Figure111
1.Coolant-accesscover
2.Bolts
3.Removetheradiatorcap(Figure112).
Figure112
1.Radiatorcap
4.Filltheradiatorwithcoolantuntiltheuidlevelisup
tothebottomofthellerneck(Figure113).
Note:Thecoolantcapacityofboththeengineand
theradiatoris16.8L(17.7USqt).
87