Operator's Manual

CheckingtheHydraulicLinesand
Hoses
ServiceInterval:Every2years—Replacemovinghoses.
Inspectthehydrauliclinesandhosesdailyforleaks,kinked
lines,loosemountingsupports,wear,loosettings,weather
deterioration,andchemicaldeterioration.Makeallnecessary
repairsbeforeoperating.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
Makesurethatallhydraulicuidhosesand
linesareingoodconditionandallhydraulic
connectionsandttingsaretightbefore
applyingpressuretothehydraulicsystem.
Keepyourbodyandhandsawayfrompin
holeleaksornozzlesthatejecthigh-pressure
hydraulicuid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
Seekimmediatemedicalattentionifuidis
injectedintoskin.
CheckingtheHydraulicSystemTest
Ports
Thetestportsareusedtotestthepressureinthehydraulic
circuits.ContactyourAuthorizedToroDealerforassistance.
Drilling-FluidPump
Maintenance
Servicingthe
Drilling-Fluid-PumpOil
Thedrilling-uidpumpisshippedwithoilinthecrankcase;
however,checktheoillevelbeforeandafteryourststart
theengine.
Thecrankcasecapacityis3.8L(4USqt).
Useonlyhigh-qualityengineoilthatmeetsthefollowing
specications:
APIClassicationLevelRequired:CH-4,CI-4or
higher
Oil:SAE80W-90,non-detergentoilaboveC(32°F)
ToroPremiumEngineOilisavailablefromyourdealer.See
thepartscatalogforpartnumbers.Also,refertotheEngine
Operator'sManual,includedwiththemachine,forfurther
recommendations.
93