Operator's Manual

2.Insertthehosefromthemixingsystemoverthepump
inlet,andsecureitwiththecam-locklevers.
SettingupthePumptoUseaNaturalWaterSource
Tosetupapumptouseanaturalwatersource,youmust
ensurethatyouusetheY-screentolterallmaterialsother
thanwater.
1.Removethepump-inletcap(Figure77).
Figure77
1.Pumpthreads3.Y-screen
2.Pump-inletcap
2.AligntheY-screenwiththethreadsonthepump
(Figure77).
3.RotateandtightentheY-screenontothepump.
4.AttachthehosetotheY-screen,andbeginpumping
fromthenaturalwatersource.
DeployingtheZap-alertSystem
TheZap-alertsystemisanelectricstrike-sensingdevice
onthemachinethattriggersastrobelightandanaudible
alarmwheneverthedrillbit,reamer,orstakebreaksintoan
energizedpowerline.Intheeventofanelectricstrike,the
machinewillbecomeenergized,settingoffthealarm.The
operator’splatformiselectricallyisolatedfromtherestof
themachinetoprotectyou.
DANGER
IftheZap-alertsystemactivateswhiledrilling,the
machine,exceptfortheoperatorplatform,will
becomeenergized.Ifyoustepofftheoperator
platformorifsomeonetouchesthemachineor
wetgroundnearthemachineorinthebore,you
ortheonewhotouchedthemachinecouldbe
electrocuted,causingseriousinjuryordeath.
TesttheZap-alertsystembeforedrilling.
Deploythegroundingstakebeforedrilling.
Ensurethatthestakeisfullyinsertedintomoist
soil.
IftheZap-alertistriggered:
Stayintheseatanddonottouchtheground
oranyotherpartofthemachineuntilthe
powerhasbeenturnedoff.Donotpour
liquidsorurinatefromtheoperatorplatform
ontotheground.
Stopdrilling,stopthedrilling-uidow,and
retractthedrilloutoftheground.
Keepeveryoneawayfromthemachine,
wetgroundnearthemachineorrunning
fromthemachine,andanyopensourcesof
water/mudthatisintheboreandcontacting
thebrokenline.
Contacttheutilitycompanytohavethe
powershutofftothebrokenline.Donot
resettheZap-alertsystemuntilthepower
hasbeenturnedoff.
1.Removethegroundingstakefromtheholderonthe
sideoftheoperatorplatform(Figure78).
67