Operator's Manual

CheckingtheOilLevelfor
theRotaryMotorPlanetary
Drive
ServiceInterval:Aftertherst100hours—Checkthe
rotarymotorplanetary-driveoillevel
(Also,checkifexternalleakageis
observed).
Every500hours—Checktherotarymotor
planetary-driveoillevel(Also,checkifexternal
leakageisobserved).
Oilspecication:SAE85W-140APIclassication
levelGL4
Planetary-driveoilcapacity:approximately0.24L
(0.5USpt)
ToroPremiumGearOilisavailablefromanAuthorized
ToroServiceDealer.Seethepartscatalogforpart
numbers.
1.Parkthemachineonalevelsurface,stopthe
engine,andremovetheignitionkey.
2.Checktheoillevelonthesight-glassonthe
rotarymotorplanetarydrive(Figure104).
Note:Theoillevelshouldbe3/4fullinthe
sight-glass.
g033968
Figure104
1.Rotarymotoroilcap
2.Sight-glass
3.Iftheoillevelislow,removetheoil-levelplug
(Figure104).
4.Installandtightentheoil-levelplug.
CheckingtheOilforthe
ThrustMotorPlanetary
Drive
ServiceInterval:Aftertherst100hours—Checkthe
thrustmotorplanetary-driveoil.
Every500hours—Checkthethrustmotor
planetary-driveoil(oryearly,whichevercomes
rst).
Oilspecication:SAE85W-140APIclassication
levelGL4
Planetary-driveoilcapacity:approximately0.24L
(0.5USpt)
1.Parkthemachineonalevelsurface,stopthe
engine,andremovetheignitionkey.
2.Checktheoillevelonthesight-glassoneach
thrustmotorplanetarydrive(Figure106).
Note:Theoillevelshouldcoverhalfofthe
sight-glass.
g034482
Figure105
1.Breathercap
2.Sight-glass
3.Removethebreathercapandaddtheoilinto
theplanetarydriveuntiltheoillevelonthe
sight-glassisatleasthalffull(Figure106).
4.Repeatforall4thrustmotorplanetarydrives.
89