Operator's Manual

AdjustingtheTensionoftheBelt
1.Parkthemachineonalevelsurface,stopthe
engine,andremovetheignitionkey.
2.Openthefronthood.
3.Loosenthenutandboltatthepivotpointforthe
alternator(Figure118).
g021648
Figure118
1.Adjustmentbolt
3.Alternator
2.Nut(alternatorpivotpoint)4.Bolt(alternatorpivotpoint)
4.Loosentheadjustmentboltonthealternator
(Figure118).
5.Movethealternatorawayfromtheengineto
increasethebelttension;movethealternator
towardtheenginetodecreasethebelttension
(Figure118).
6.Tightenthealternatoradjustmentbolt(Figure
118).
7.Checkthetensionofthebelt;refertoChecking
theTensionoftheBelt(page97).
8.Ifthebelttensioniscorrect,tightenthenutand
boltatthepivotpointforthealternator(Figure
118);otherwise,repeatsteps4through7.
HydraulicSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
ServicingtheHydraulic
Fluid
Thehydraulicreservoirislledatthefactorywith
approximately170L(45USgallons)ofhigh-quality
hydraulicuid.Checkthelevelofthehydraulic
uidbeforetheengineisrststartedanddaily
thereafter.Therecommendedreplacementuidas
follows:
ToroPremiumAllSeasonHydraulicFluid
(Availablein5gallonpailsor55gallondrums.Contact
yourAuthorizedToroDealerforpartnumbers.)
Alternateuids:IftheTorouidisnotavailable,other
uidsmaybeusedprovidedtheymeetallthefollowing
materialpropertiesandindustryspecications.Wedo
notrecommendtheuseofsyntheticuid.Consultwith
yourlubricantdealertoidentifyasatisfactoryproduct.
Note:T orowillnotassumeresponsibilityfordamage
causedbyimpropersubstitutions,souseonly
productsfromreputablemanufacturerswhowillstand
behindtheirrecommendation.
HighViscosityIndex/LowPourPoint
Anti-wearHydraulicFluid,ISOVG46
MaterialProperties:
42.2cStat40°C(104°F)
Viscosity,ASTMD445
7.8cStat100°C(212°F)
ViscosityIndexASTM
D2270
158
98