12.InstallthehoseshowninFigure42.
13.Fillthehydraulictankwithapproximately25.8L(6.8
USgallons)ofToropremiumallseasonhydraulicuid
ISOVG46;refertoCheckingtheHydraulicFluid
Level(page16).
Disposeoftheusedoilatacertiedrecyclingcenter.
14.Installthedipstickcap.
15.Starttheengineandletitrunforafewminutes.
16.Stoptheengine.
17.Checkthehydraulicuidlevelandtopitoffif
necessary;referto
CheckingtheHydraulicFluidLevel
(page16).
CheckingtheHydraulicLines
ServiceInterval:Every100hours—Checkthehydraulic
linesforleaks,loosettings,kinkedlines,
loosemountingsupports,wear,weather,
andchemicaldeterioration.(Make
necessaryrepairsbeforeoperating.)
Every1,500hours/Every2years(whichevercomes
rst)—Replaceallmovinghydraulichoses.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjectedinto
theskinmustbesurgicallyremovedwithinafew
hoursbyadoctorfamiliarwiththisformofinjury
organgrenemayresult.
Keepyourbodyandhandsawayfrompin
holeleaksornozzlesthatejecthighpressure
hydraulicuid.
Usecardboardorpapertondhydraulicleaks,
neveruseyourhands.
35