Operator's Manual

1
g018923
Figure40
1.Hydraulic-oillter
5.Applyathincoathydraulicuidtotherubbergasket
onthereplacementlter.
6.Installthereplacementhydrauliclterontothelter
head.Tightenitclockwiseuntiltheltercontactsthe
lterhead,thentightenthelteranadditional3/4turn.
7.Fillthehydrauliclterwithcleanhydraulicuid.
8.Cleanupanyspilleduid.
9.Starttheengineandletitrunforabout2minutesto
purgeanyairfromthesystem.
10.Stoptheengineandcheckforleaks.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjected
intotheskinmustbesurgicallyremoved
withinafewhoursbyadoctorfamiliarwith
thisformofinjuryorgangrenemayresult.
Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthatejecthigh
pressurehydraulicuid.
Usecardboardorpapertondhydraulic
leaks,neveruseyourhands.
CheckingtheHydraulicFluidLevel
ServiceInterval:Beforeeachuseordaily
Important:Alwaysusethecorrecthydraulicuid.
Unspecieduidswilldamagethehydraulicsystem.
1.Parkthemachineonalevelsurfaceandlowerany
attachments.
2.Stoptheengine,removethekey,andallowtheengine
tocool.
3.Openthehood.
4.Cleantheareaaroundthellerneckofthehydraulic
tank(Figure41).
1
g018957
Figure41
1.Hydraulictank
5.Removethecapfromthellerneckandchecktheuid
levelonthedipstick(Figure42).
Theuidlevelshouldbebetweenthemarksonthe
dipstick.
Figure42
1.Fillerneck2.Dipstick
6.Ifthelevelislow,addenoughuidtoraiseittothe
properlevel.
7.Installthecaponthellerneck.
8.Closethehood.
ChangingtheHydraulicFluid
ServiceInterval:Aftertherst250hours
Every1,000hours/Yearly(whichevercomesrst)
1.Positionthemachineonalevelsurface.
2.Removethehydraulictankcap.
3.Placealargedrainpan(capableofholding15US
gallons)onthegroundunderthehydraulictank.
4.Disconnecttheelectricalleadtotheoiltemperature
sendingunitatthebottomofthereservoir.
32