Operator's Manual

1
InstallingtheHydraBorer
Motor
Partsneededforthisprocedure:
1Motor
1Adapter
1Retaineradapter
1Lockwasher
1
Bolt(1/2x1-1/4inches)
2
90-degree,elbowtting
2
Hose,114.3cm(45inches)
1Bracket
8
Bolt(1/2x1-3/4inch)
8
Flatwasher(1/2inch)
8
Locknut(1/2inch)
1Jointassembly
1
Nut(3/8inch)
1
Bolt(3/8x2-1/2inch)
Procedure
1.Greasetheshaftofthemotorandplacetheadapter
ontothemotor(Figure1).
1
2
3
4
g021919
5
Figure1
1.Bolt(1/2x1-1/4inch)
4.Adapter
2.Lockwasher5.Motor
3.Retaineradapter
2.Puttheretaineradapterontheadapter.
3.Placethewasherontheboltandapplythread-locking
adhesivetothebolt.
4.Securethebolttotheadapters;torqueto160to165
N-m(118to122ft-lb).
5.Install2ofthe90-degree,elbowttingsintotheports
onthemotor(
Figure2).
g021920
Figure2
6.Attachthe114.3cm(45inch)hosestotheelbow
ttingsonthemotor(Figure3).
g021921
Figure3
7.Securethebrackettothemotorusingthe4bolts(1/2
x13/4inch),the4atwashers(1/2inch),andthe4
locknuts(1/2inch)(Figure4);torqueto140to144
N-m(100to110ft-lb).